where is the bare shield wire I dont see it in the picture?
also lets hook up the motor ends first, before hooking it to the controller and test with the ohm meter ok? ( your colors are correct on the controller )
you have your heat shrink right?
steve
no problem i just didnt see the shield wire anywhere, i was concerned they gave us the wrong wire.
the shield is there not in view in pic right?
yes we will connect motors first and test everything, heat shrink and retest then hook to controllers
colors are correct red red, black black, green green, and hook white to blue at motors.
shorts here can cause fire 36v 10a or controller damage
shorts to the controller from breakout board just cause malfunction
be back in a few minutes having home phone trouble i have to check ( fussing wife lol )
steve
ok phone is fixed wife happy
there should be 5 wires in your cable 4 insulated red,black,green,white and also a uninsulated shield wire
i only see 4 wires in the pic no bare wire that is the shield.
ok thats not the wire we wanted but we can use it outside the enclosure from your connectors to wire the motors.
I'll find what we need for everything else and post it here
I am sorry
steve